Release Notes 6.0.60

What’s new in the latest version of Indeni? Enhancements in the core platform across Indeni Server, Collector, and Knowledge.

See below for the detailed notes for 6.0.60 included in this platform release. Customers head over to the Indeni Forum to join the conversation around these capabilities or explore our learning paths. Want the latest build? Download the latest version.

Improvements

Check Point

  • Reduced impact on embedded GAiA
  • “Failed to communicate” – secondary MDS and MLM
  • IPSO – improved “cluster down” alert – VRRP
  • Names in scripts “detect-management-interrogation” improved to remove duplicates
  • Parser returning input failure – chkp-os-failed-login improved
  • snmp-enabled written twice per run of ind script
  • Alert will trigger when metric log-file-size increases
  • Throughput alert will trigger based on VSID
  • Alert will trigger when Core dump files found
  • Live config for cluster information corrected parameter
  • If a cluster member is passing traffic, the “cluster” is still up; no alert will be issued

Cross-Vendor

  • “License expired” added option to ignore licenses expiration more than ‘x’ months ago
  • Duplicate Rules Removal

New features

Check Point

  • Alerted when there are repeated unsuccessful logon attempts
  • Improved description in #!COMMENTS section for description in vpn-check-tunnels-novsx.ind
  • Updated IND script with further documentation to include #!COMMENTS section
  • IPSO – interface and cluster state logic improvements
  • Improved logic in IND script to rewrite ntpq-p.ind to not use ntp-servers

Cisco Nexus

  • Improved remediation steps for select Cisco Nexus rules
  • Updated template rule “NextHopRouterInaccessibleRule”, adding remediation text for nexus
  • Removed duplicate command names in IND scripts
  • Created a new alert monitoring changes of “spanning-tree-root” metrics
  • Ensured SNMP communities are enabled with an ACL
  • Modified snmp-enabled from enabled/disabled to true/false
  • Ensured that SNMPv3 is configured, validate that SNMP requires authentication or encryption for all incoming requests
  • Monitored the results from the diagnostic tests for the Nexus Fabric Extender chassis
  • Unexpected too high number of commands are executed from the Indeni Server

Cross-Vendor

  • RULE: missing rule to detect when snmp is public

F5

  • Alert created for “Reset cause packet details enabled”

Palo Alto Networks

  • Alert on environmental temperature value based on threshold
  • Added new metric “missing-power-supply”, introduce “hardware-element-state” for PAN power supplies, and new alert “Power Supply Missing”

BlueCat acquires Indeni to boost its industry-leading DNS, DHCP and IP address management platform to help customers proactively assess network health and prevent outages.